ALSTOM GE Auxiliary Relays

Pioneers in the industry, we offer alstom numerical generator protection relay agile p14dg, alstom / ge micom p343 generator protection numerical relay, alstom / ge micom p346 generator protection numerical relays, alstom generator protection relay micom p343711a2m0380m, alstom generator protection relay micom p343911a2m0380m and alstom generator protection relay micom p343911e2m0380m from India.

Alstom Numerical Generator Protection Relay Agile P14DG

Request Callback

Get Latest Price

BrandAlstom
Voltage24V-240V
Model Name/NumberP14DG
Usage/ApplicationGenerator Protection Relay
relay applicationGenerator Protection Relay
ALSTOM NUMERICAL GENERATOR PROTECTION RELAY AGILE P14DGType: Numerical Relay
Protection Type: Generator
P40 Agile Feeder Management
The P14N non-directional feeder, P14D directional feeder and P94V voltage and frequency IEDs bring the design rigor and technology of transmission applications to the entire utility and industrial market. The footprints of both the device physical size and the lifecycle environmental impact have been minimized using state-of-the-art design, component, and process selection. Agile solutions from GE are ideal for new-build and retrofit alike.
Agility and Versatility
MiCOM P40 Agile IEDs provide an integrated solution for the complete protection, control and monitoring of electrical power systems. Application for overhead lines, underground cables, busbars, breakers, transformers, reactors and distributed generation is supported, right from distribution (as primary protection) to transmission voltage levels (as back-up). The IEDs are suitable for a wide variety of applications in solidly-earthed, resistance-earthed and Petersen coil systems.
Key Benefits
Comprehensive current, voltage, power and frequency protectionMulti-stage independent protection elements, customizable curvesUniversal power supply, binary input ratings and 1A/5A CT – avoids order optionsRecords up to 2048 events, graphical logic engine, distance-to-fault locationTwo stage circuit breaker failure and breaker condition monitoringSwitchgear supervision including CT/VT, DC supply, full ‘H7’ trip circuit supervisionSubstation communications including IEC 61850, serial and concurrent protocolsCompact, withdrawable design for reduced space applicationsEcodesigned with Product Environmental Profile (PEP), no resident battery

Alstom / GE Micom P343 Generator Protection Numerical Relay

Request Callback

Get Latest Price

BrandGE
Voltage24V-240V
Model Name/NumberP343
Usage/ApplicationVoltage Relay
application relayVoltage Relay
ALSTOM / GE MICOM P343 GENERATOR PROTECTION NUMERICAL RELAYThe MiCOM Alstom  P343 generator protection relay have been designed for the protection of a wide range of generators.
The Micom Alstom P343 relay is suitable for protection of medium to large size generators (>10 MVA) or more important generators, providing generator differential, 100% stator earth fault via a 3rd harmonic measuring technique, pole slipping and unintentional energisation at standstill protection in addition to the features of the P342.
The P343 supports the following relay management functions in addition to the functions shown above.
Measurement of all instantaneous & integrated valuesCircuit breaker control, status & condition monitoringTrip circuit and coil supervision4 Alternative setting groupsProgrammable function keys (P343/4/5/6)Control inputsProgrammable scheme logicProgrammable allocation of digital inputs and outputsSequence of event recordingComprehensive disturbance recording (waveform capture)Fault recordingFully customizable menu textsMulti-level password protectionPower-up diagnostics and continuous self-monitoring of relayCommissioning test facilitiesReal time clock/time synchronization – time synchronization possible from IRIG-B input, opto input or communicationsGE’s Agile P343 generator protection solutions provide extensive functionality to meet all generator and generator – transformer applications, including differential protection for fast and selective tripping of phase and earth faults. All generator protection, control, monitoring, recording and communications components are housed within one box, and the solutions are accompanied by a comprehensive library of hardware options, protection and control functions to meet system requirements.
Key benefits:
Extensive condition based monitoring features for generators and transformersGraphical programmable scheme logic eases protection scheme creation and avoids the need for external logic controllersRange of different protocols (MODBUS, DNP3, IEC 60870-5-103 and IEC 61850) are availableIEC 61850 / DNP3.0 redundant Ethernet, supporting self healing ring, RSTP, dual homing or PRPProgrammable curves for easy protection customizationMain characteristics:
Sensitive rotor earth fault protection using low frequency injection methodHarsh Environment Option to protect against corrosive gases such as H2S or SO2Generator and transformer thermal overload, transformer loss of life and through fault monitoringExtensive protection for large machines such as pole slipping and 100% stator earth fault protection (3rd harmonic and low frequency injection method)TYPE: NUMERICAL RELAY
• Protection Type: Generator
• Voltage 24V-240V
• ACDC Operated: Auxillary supply AC/DC
MiCOM ALSTOM is a comprehensive solution capable of meeting all electricity supply requirements. It comprises a range of components, systems and services from Alstom Grid. Central to the MiCOM ALSTOM concept is flexibility. MiCOM ALSTOM provides the ability to define an application solution and, through extensive communication capabilities, integrate it with your power supply control system.
Our products include extensive facilities for recording information on the state and behavior of the power system using disturbance and fault records. They can also provide measurements of the system at regular intervals to a control center enabling remote monitoring and control to take place. For up-to-date information on any MiCOM ALSTOM product, visit us!

Alstom / GE Micom P346 Generator Protection Numerical Relays

Request Callback

Get Latest Price

BrandAlstom
Voltage24V-240V
Model Name/NumberP346
Usage/ApplicationGenerator Protection Numerical relay
relay applicationGenerator Protection Numerical relay
ALSTOM / GE MICOM P346 GENERATOR PROTECTION NUMERICAL RELAYThe MiCOM Alstom  P346 generator protection relay have been designed for the protection of a wide range of generators.
The Alstom P346 is suitable for the protection of medium to large size generators and is the same as the P343 but without 100% stator earth fault, pole slipping and dead machine protection.
The P346 also includes 10 function keys for integral scheme or operator control functionality and tri-color (red/yellow/green) LEDs. Rotor earth fault protection is provided by the P391 low frequency square wave injection, coupling and measurement unit connected to the rotor circuit. The measurement of the rotor resistance is passed to the P346 via a current loop output (0-20 mA) on the P391 connected to one of the 4 current loop inputs onthe P346. The rotor ground fault protection is only available if the relay includes the CLIO hardware option.
The Micom P346 supports the following relay management functions in addition to the functions shown above.
Measurement of all instantaneous & integrated valuesCircuit breaker control, status & condition monitoringTrip circuit and coil supervision4 Alternative setting groupsProgrammable function keys (P343/4/5/6)Control inputsProgrammable scheme logicProgrammable allocation of digital inputs and outputsSequence of event recordingComprehensive disturbance recording (waveform capture)Fault recordingFully customizable menu textsMulti-level password protectionPower-up diagnostics and continuous self-monitoring of relayCommissioning test facilitiesReal time clock/time synchronization – time synchronization possible from IRIG-B input, opto input or communicationsGE’s Agile P346 generator protection solutions provide extensive functionality to meet all generator and generator – transformer applications, including differential protection for fast and selective tripping of phase and earth faults. All generator protection, control, monitoring, recording and communications components are housed within one box, and the solutions are accompanied by a comprehensive library of hardware options, protection and control functions to meet system requirements.
Key benefits:
Extensive condition based monitoring features for generators and transformersGraphical programmable scheme logic eases protection scheme creation and avoids the need for external logic controllersRange of different protocols (MODBUS, DNP3, IEC 60870-5-103 and IEC 61850) are availableIEC 61850 / DNP3.0 redundant Ethernet, supporting self healing ring, RSTP, dual homing or PRPProgrammable curves for easy protection customizationMain characteristics:
Sensitive rotor earth fault protection using low frequency injection methodHarsh Environment Option to protect against corrosive gases such as H2S or SO2Generator and transformer thermal overload, transformer loss of life and through fault monitoringExtensive protection for large machines such as pole slipping and 100% stator earth fault protection (3rd harmonic and low frequency injection method)TYPE: NUMERICAL RELAY
• Protection Type: Generator
• Voltage 24V-240V
• ACDC Operated: Auxillary supply AC/DC
MiCOM ALSTOM is a comprehensive solution capable of meeting all electricity supply requirements. It comprises a range of components, systems and services from Alstom Grid. Central to the MiCOM ALSTOM concept is flexibility. MiCOM ALSTOM provides the ability to define an application solution and, through extensive communication capabilities, integrate it with your power supply control system.

Alstom Generator Protection Relay Micom P343711A2M0380M

Request Callback

Get Latest Price

BrandGE
Voltage220/240 V
Model Name/NumberP343
Usage/ApplicationVoltage Relay
relay applicationVoltage Relay
ALSTOM GENERATOR PROTECTION RELAY MICOM P343711A2M0380MTechnical Specification
Type: Numerical Relay Protection
Generator Protection SystemsGE’s MiCOM Agile P34x generator protection relays provide flexible and reliable integration of protection, control, monitoring and measurement functions for a wide range of applications. The P34x relay platform is available in six models that cover most installations from small generators to sophisticated systems including generator-transformer applications and large variable speed double fed induction pumped storage machines.
Key features:
Comprehensive protection functions, flexible communications options with a number of protocols and portsGenerator turbine abnormal frequency protection monitors the accumulated time spent at each frequency bandCheck synchronization function with an option to compensate for magnitude and phase angleUser-friendly programmable scheme logic allows easy customization of the protection and control functionsCurrent loop analogue inputs and outputs for remote monitoringNo internal batteries in GE-branded models – removes a maintenance item and eases air-freight logisticsBinary inputs ESI48-4 EB2 compliantBinary inputs offer programmable pickup voltage thresholds and filtering enabling a truly universal applicationHigh break output contacts eliminate reliance on auxiliary devicesUnique low frequency protection for variable speed double fed induction machinesRotor earth fault protectionHarsh environment protection extends the life of the productOpens in a new window

Alstom Generator Protection Relay Micom P343911A2M0380M

Request Callback

Get Latest Price

BrandGE
Voltage220/240 V
Model Name/NumberP343
Usage/ApplicationGenerator Protection Relay
relay applicationOverload Relay
ALSTOM GENERATOR PROTECTION RELAY MICOM P343911A2M0380MTechnical Specification
Type: Numerical Relay
Protection Type: Generator
Generator Protection SystemsGE’s MiCOM Agile P34x generator protection relays provide flexible and reliable integration of protection, control, monitoring and measurement functions for a wide range of applications. The P34x relay platform is available in six models that cover most installations from small generators to sophisticated systems including generator-transformer applications and large variable speed double fed induction pumped storage machines.
Key features:
Comprehensive protection functions, flexible communications options with a number of protocols and portsGenerator turbine abnormal frequency protection monitors the accumulated time spent at each frequency bandCheck synchronization function with an option to compensate for magnitude and phase angleUser-friendly programmable scheme logic allows easy customization of the protection and control functionsCurrent loop analogue inputs and outputs for remote monitoringNo internal batteries in GE-branded models – removes a maintenance item and eases air-freight logisticsBinary inputs ESI48-4 EB2 compliantBinary inputs offer programmable pickup voltage thresholds and filtering enabling a truly universal applicationHigh break output contacts eliminate reliance on auxiliary devicesUnique low frequency protection for variable speed double fed induction machinesRotor earth fault protectionHarsh environment protection extends the life of the product

Alstom Generator Protection Relay Micom P343911E2M0380M

Request Callback

Get Latest Price

BrandGE
Voltage24V-240V
Model Name/NumberP343
Usage/ApplicationVoltage Relay
relay applicationVoltage Relay
ALSTOM GENERATOR PROTECTION RELAY MICOM P343911E2M0380MTechnical Specification
Type: Numerical Relay
Protection Type: Generator
Generator Protection SystemsGE’s MiCOM Agile P34x generator protection relays provide flexible and reliable integration of protection, control, monitoring and measurement functions for a wide range of applications. The P34x relay platform is available in six models that cover most installations from small generators to sophisticated systems including generator-transformer applications and large variable speed double fed induction pumped storage machines.
Key features:
Comprehensive protection functions, flexible communications options with a number of protocols and portsGenerator turbine abnormal frequency protection monitors the accumulated time spent at each frequency bandCheck synchronization function with an option to compensate for magnitude and phase angleUser-friendly programmable scheme logic allows easy customization of the protection and control functionsCurrent loop analogue inputs and outputs for remote monitoringNo internal batteries in GE-branded models – removes a maintenance item and eases air-freight logisticsBinary inputs ESI48-4 EB2 compliantBinary inputs offer programmable pickup voltage thresholds and filtering enabling a truly universal applicationHigh break output contacts eliminate reliance on auxiliary devicesUnique low frequency protection for variable speed double fed induction machinesRotor earth fault protectionHarsh environment protection extends the life of the product

Alstom Generator Protection Relay Micom P345

Request Callback

Get Latest Price

BrandGE
Voltage220/240 V
Model Name/NumberP345
Usage/ApplicationFrequency Relay
relay applicationFrequency Relay
GE/ ALSTOM MICOM AGILE P345 GENERATOR PROTECTION RELAYSGE’s Alstom MiCOM Agile P345 generator protection relays provide flexible and reliable integration of protection, control, monitoring and measurement functions for a wide range of applications. The P345 relay platform is available in seven models that cover most installations from small generators to sophisticated systems including generator-transformer applications and large variable speed double fed induction pumped storage machines.
Key features:
Comprehensive, flexible communications options with a number of protocols and ports availableUser-friendly programmable scheme logic allows easy customization of the protection and control functionsBinary inputs offer programmable pickup voltage thresholds and filtering enabling a truly universal applicationHigh break output contacts eliminate reliance on auxiliary devicesUnique low frequency protection for variable speed double fed induction machinesRotor earth fault protection

Alstom Numerical Feeder Protection Relay Agile P14nb

Request Callback

Get Latest Price

voltage24-240V
usagefeeder protection
brandGE
MODEL NOP14NB
RELAY APPLICATIONfeeder protection
ALSTOM NUMERICAL FEEDER PROTECTION RELAY AGILE P14NB PROTOCOL AVAILABLE:- MODBUS / IEC103 / 61850Technical Specification
• Type: Numerical Relay
• Protection Type: Feeder
• Protocol: Modbus / IEC103 / 61850
• Voltage: 24V-240V
P40 Agile Feeder Management The P14N non-directional feeder, P14D directional feeder and P94V voltage and frequency IEDs bring the design rigour and technology of transmission applications to the entire utility and industrial market. The footprints of both the device physical size and the lifecycle environmental impact have been minimised using state-of-the-art design, component, and process selection. Agile solutions from GE are ideal for new-build and retrofit alike.
Agility and Versatility
MiCOM P40 Agile IEDs provide an integrated solution for the complete protection, control and monitoring of electrical power systems. Application for overhead lines, underground cables, busbars, breakers, transformers, reactors and distributed generation is supported, right from distribution (as primary protection) to transmission voltage levels (as back-up). The IEDs are suitable for a wide variety of applications in solidly-earthed, resistanceearthed and Petersen coil systems alike
Protection and Control
Comprehensive current, voltage, power and frequency protection functions
Multi-stage independent protection elements, variety of curves in 4 setting groups
High Impedance Fault, Load Encroachment, Switch onto fault and Fault Locator
Rate of change, full-scheme auto-reclose, TEFD and synchrocheck
Metering and Monitoring
Comprehensive metering & power-up diagnostics
Two stage circuit breaker failure and breaker condition monitoring
Switchgear supervision including CT/VT, DC supply, full Trip Circuit Supervision, CB failure
Switch control and status (up to 8) and up to 2048 events and 10.5 s disturbance records
AdvancedCommunications
Up to two Ethernet ports with options for redundancy protocols (RSTP or PRP/HSR) SNTP or IRIG-B time synchronization
Multiple communication protocols including IEC 61850, Modbus, DNP 3.0, IEC 60870-5-103 and Courier/K-Bus
Support IEC 61850 and DNP3 Ethernet protocol working concurrently

Alstom OCEF Protection (IDMT Relay) CDG31EG002SBCH, CDG31EG002SBCH

Request Callback

Get Latest Price

TypeIndustrial Relay
Frequency50 / 60Hz
Voltage220-240V
BRANDGE
MODELCDG31EG002SBCH, CDG31EG002SBCH
USAGE / APPLICATIONOvercurrent and Earthfault protection
Alstom cdg31eg002sbchtechnical specification
type: electro mechanical relayprotection type: over current & earth fault protection(idmt relay)gbcdg31eg002sbchnon directional inv time 3o/c or 2o/c&1emodel no                  –  cdg31eg002sbchrelay type                –  cdg 31application               –  2 o/c + 1 e/fburden / d. M. T            –  3 va / 3 sec. C. T. Secondary            –  5 amp c. T. Case size                 –  3d horz. Contacts (s/r or h/r)     –  2 n/o s/re/f  setting              –  0. 5 – 2 amps. Flag                      –  yesfrequency                 –  50 hzmounting                  –  flusho/c   setting             –  2. 5 – 10 amps. Name plate                –  rfg9126 903outline diagram              mfj 014
alstom cdg31eg012sbchtechnical specification
type: electro mechanical relayprotection type: over current & earth fault protection(idmt relay)gbcdg31eg012sbchnon directional inv time 3o/c or 2o/c&1emodel no                  –  cdg31eg012sb(m)relay type                –  cdg 31application               –  2 o/c + 1 e/fburden / d. M. T            –  3 va / 1. 3 sec. C. T. Secondary            –  5 amp c. T. Case size                 –  3d horz. Contacts (s/r or h/r)     –  2 n/o s/re/f  setting              –  0. 5 – 2 amps. Flag                      –  yesfrequency                 –  50 hzmounting                  –  flusho/c   setting             –  2. 5 – 10 amps. Name plate                –  rfg9125 903outline diagram              mfj014wiring diagram               madz802. 63-1

Ge/ Alstom Numerical Motor Protection Relay Agile P242, P243

Request Callback

Get Latest Price

Voltage220-240V
brandingGE
usageMotor protection
model noP242 / 243
relay applicationMotor protection
GE/ ALSTOM NUMERICAL MOTOR PROTECTION RELAY AGILE P242
The Agile P24xM Motor Management Series, a member of the field proven P40 Agile protective relay platform, and has been designed for the protection, control, and management of medium voltage motors in industrial applications. The P24xM series offers a small, flexible form factor, advanced and redundant communications, multiple I/O options, and is available with current inputs (P24NM) or with current and voltage inputs (P24DM). The P24xM series delivers reliable protection for pumps, conveyors, fans, and compressors to ensure maximum process uptime.

Features:

Cost-effective, flexible protection and control for medium voltage motors
Field-proven algorithms and reliable protection to avoid unwanted trips or under-protection
Ease of integration and standardization with universal CT inputs and multiple case sizes
Time stamped event reports and waveform capture, simplifying post-event analysis
Powerful security and hierarchical password control for centralized management
Advanced power system and switchgear diagnostics
Application flexibility with user programmable motor overload curve, comprehensive start sequence and re-acceleration scheme
Drawout design simplifies testing, commissioning and maintenance for increased process uptime
Redundant communications with multiple ports and protocols allowing seamless integration with SCADA and DCS systems
Ease of use with intuitive device configuration software and user-friendly logic configuration tool

GE / ALSTOM NUMERICAL MOTOR PROTECTION RELAY AGILE P243
The Agile P24xM Motor Management Series, a member of the field proven P40 Agile protective relay platform, and has been designed for the protection, control, and management of medium voltage motors in industrial applications. The P24xM series offers a small, flexible form factor, advanced and redundant communications, multiple I/O options, and is available with current inputs (P24NM) or with current and voltage inputs (P24DM). The P24xM series delivers reliable protection for pumps, conveyors, fans, and compressors to ensure maximum process uptime.

Features:

Cost-effective, flexible protection and control for medium voltage motors
Field-proven algorithms and reliable protection to avoid unwanted trips or under-protection
Ease of integration and standardization with universal CT inputs and multiple case sizes
Time stamped event reports and waveform capture, simplifying post-event analysis
Powerful security and hierarchical password control for centralized management
Advanced power system and switchgear diagnostics
Application flexibility with user programmable motor overload curve, comprehensive start sequence and re-acceleration scheme
Drawout design simplifies testing, commissioning and maintenance for increased process uptime
Redundant communications with multiple ports and protocols allowing seamless integration with SCADA and DCS systems
Ease of use with intuitive device configuration software and user-friendly logic configuration tool

Alstom Generator Protection Relay Micom P342

Request Callback

Get Latest Price

BrandGE
Voltage220/240 V
Model Name/NumberP342
Usage/ApplicationVoltage Relay
relay applicationVoltage Relay
ALSTOM GENERATOR PROTECTION RELAY MICOM P342GE’s MiCOM Agile P342 generator protection relays provide flexible and reliable integration of protection, control, monitoring and measurement functions for a wide range of applications. The P342 relay platform is available in seven models that cover most installations from small generators to sophisticated systems including generator-transformer applications and large variable speed double fed induction pumped storage machines.
Key features:
Comprehensive, flexible communications options with a number of protocols and ports availableUser-friendly programmable scheme logic allows easy customization of the protection and control functionsBinary inputs offer programmable pickup voltage thresholds and filtering enabling a truly universal applicationHigh break output contacts eliminate reliance on auxiliary devicesUnique low frequency protection for variable speed double fed induction machinesRotor earth fault protectionKey benefits:
Extensive condition based monitoring features for generators and transformersGraphical programmable scheme logic eases protection scheme creation and avoids the need for external logic controllersRange of different protocols (MODBUS, DNP3, IEC 60870-5-103 and IEC 61850) are availableIEC 61850 / DNP3.0 redundant Ethernet, supporting self healing ring, RSTP, dual homing or PRPProgrammable curves for easy protection customizationMain characteristics:
Sensitive rotor earth fault protection using low frequency injection methodHarsh Environment Option to protect against corrosive gases such as H2S or SO2Generator and transformer thermal overload, transformer loss of life and through fault monitoringExtensive protection for large machines such as pole slipping and 100% stator earth fault protection (3rd harmonic and low frequency injection method)

Alstom Generator Protection Relay Micom P343916A6M0380M

Request Callback

Get Latest Price

BrandGE
Voltage24V-240V
Model Name/NumberP343
Usage/ApplicationVoltage Relay
relay applicationVoltage Relay
Alstom Generator Protection relay Micom P343916A6M0380MTechnical Specification
Type: Numerical Relay
Protection Type: Generator
Generator Protection SystemsGE’s MiCOM Agile P34x generator protection relays provide flexible and reliable integration of protection, control, monitoring and measurement functions for a wide range of applications. The P34x relay platform is available in six models that cover most installations from small generators to sophisticated systems including generator-transformer applications and large variable speed double fed induction pumped storage machines.
Key features:
Comprehensive protection functions, flexible communications options with a number of protocols and portsGenerator turbine abnormal frequency protection monitors the accumulated time spent at each frequency bandCheck synchronization function with an option to compensate for magnitude and phase angleUser-friendly programmable scheme logic allows easy customization of the protection and control functionsCurrent loop analogue inputs and outputs for remote monitoringNo internal batteries in GE-branded models – removes a maintenance item and eases air-freight logisticsBinary inputs ESI48-4 EB2 compliantBinary inputs offer programmable pickup voltage thresholds and filtering enabling a truly universal applicationHigh break output contacts eliminate reliance on auxiliary devicesUnique low frequency protection for variable speed double fed induction machinesRotor earth fault protectionHarsh environment protection extends the life of the product

Alstom Generator Protection Relay Micom P344

Request Callback

Get Latest Price

BrandGE
Voltage24V-240V
Model Name/NumberP344
Usage/ApplicationVoltage Relay
relay applicationVoltage Relay
GE/ ALSTOM GENERATOR PROTECTION RELAY MICOM P344Generator Protection SystemsGE’s MiCOM Agile P34x generator protection relays provide flexible and reliable integration of protection, control, monitoring and measurement functions for a wide range of applications. The P34x relay platform is available in seven models that cover most installations from small generators to sophisticated systems including generator-transformer applications and large variable speed double fed induction pumped storage machines.
Key features:
Comprehensive, flexible communications options with a number of protocols and ports availableUser-friendly programmable scheme logic allows easy customization of the protection and control functionsBinary inputs offer programmable pickup voltage thresholds and filtering enabling a truly universal applicationHigh break output contacts eliminate reliance on auxiliary devicesUnique low frequency protection for variable speed double fed induction machinesRotor earth fault protectionGE’s Agile P34x generator protection solutions provide extensive functionality to meet all generator and generator – transformer applications, including differential protection for fast and selective tripping of phase and earth faults. All generator protection, control, monitoring, recording and communications components are housed within one box, and the solutions are accompanied by a comprehensive library of hardware options, protection and control functions to meet system requirements.
Key benefits:
Extensive condition based monitoring features for generators and transformersGraphical programmable scheme logic eases protection scheme creation and avoids the need for external logic controllersRange of different protocols (MODBUS, DNP3, IEC 60870-5-103 and IEC 61850) are availableIEC 61850 / DNP3.0 redundant Ethernet, supporting self healing ring, RSTP, dual homing or PRPProgrammable curves for easy protection customizationMain characteristics:
Sensitive rotor earth fault protection using low frequency injection methodHarsh Environment Option to protect against corrosive gases such as H2S or SO2Generator and transformer thermal overload, transformer loss of life and through fault monitoringExtensive protection for large machines such as pole slipping and 100% stator earth fault protection (3rd harmonic and low frequency injection method)

Alstom Motor Protection Relay Agile P253 Numerical Relay

Request Callback

Get Latest Price

Usage/ApplicationMotor protection
Voltage220-240V
brandingGE
model noP253
relay applicationMotor protection
GE/ ALSTOM MOTOR PROTECTION RELAY AGILE P253 NUMERICAL RELAY
The P50 Agile P253 provides basic motor protection for small and medium size MV/LV motors. It includes a wide range of measurements for motor supervision and operations including starting current record, and features flexible SCADA communication options such as Modbus/IEC 60870-5-103 or DNP3.0.

The principal protection functions include thermal overload, negative sequence overcurrent, loss of load, prolonged start,  locked rotor (starting / normal running), restricted earth fault, excessive number of starts and speed switch input. Additional versatility is provided through backup overcurrent and earth fault protection, with up to 3 independent stages, breaker fail and trip circuit supervision functions. The hardware capability is broadened by a sensitive earth fault CT option.

Key Features

Optimized protection for motor applications
Cost effective solution
Measurement, protection and monitoring in one box
Front USB port for local communication
Flexible SCADA communication options
Diagnostics/maintenance facilities Universal, wide-range auxiliary supply for procurement and inventory standardization
Same form factor for feeder/motor relays
Password protection for security
Extensive self-supervision and internal diagnostics

Alstom Motor Protection Relay Micom P241 Numerical Relay

Request Callback

Get Latest Price

voltage-220-240V
brandingGE
usageMotor protection
model noP241
relay applicationMotor protection
GE/ ALSTOM MOTOR PROTECTION RELAY MICOM P241 NUMERICAL RELAY
The Agile P24xM Motor Management Series, a member of the field proven P40 Agile protective relay platform, and has been designed for the protection, control, and management of medium voltage motors in industrial applications. The P24xM series offers a small, flexible form factor, advanced and redundant communications, multiple I/O options, and is available with current inputs (P24NM) or with current and voltage inputs (P24DM). The P24xM series delivers reliable protection for pumps, conveyors, fans, and compressors to ensure maximum process uptime.

 

Cost-effective, flexible protection and control for medium voltage motors
Field-proven algorithms and reliable protection to avoid unwanted trips or under-protection
Ease of integration and standardization with universal CT inputs and multiple case sizes
Time stamped event reports and waveform capture, simplifying post-event analysis
Powerful security and hierarchical password control for centralized management
Advanced power system and switchgear diagnostics
Application flexibility with user programmable motor overload curve, comprehensive start sequence and re-acceleration scheme
Drawout design simplifies testing, commissioning and maintenance for increased process uptime
Redundant communications with multiple ports and protocols allowing seamless integration with SCADA and DCS systems
Ease of use with intuitive device configuration software and user-friendly logic configuration tool

Alstom Over Current & Earth Fault Protection CDG11AF006SACH, CDG11AF006SACH

Request Callback

Get Latest Price

Voltage220-240V
brandAlstom
usageOvercurrent and Earthfault protection
model noCDG11A
relay applicationOvercurrent and Earthfault protection
Alstom Over current & Earth fault Protection CDG11AF006SACH
Technical Specification

Type: Electro Mechanical Relay
Protection Type: Over current & Earth fault Protection(IDMT Relay)
GBCDG11AF006SACH
SELF-POWERED INVERSE TIME O/C OR E/F REL

Alstom OCEF Protection (IDMT Relay) CDG11AF003SACH, CDG11AF004SACH

Request Callback

Get Latest Price

Voltage220-240V
brandingAlstom / GE
model noCDG11A
usageOvercurrent and Earthfault protection
relay applicationOvercurrent and Earthfault protection
Alstom Over current & Earth fault Protection (IDMT relay) CDG11AF003SACHGBCDG11AF003SACHSELF-POWERED INVERSE TIME O/C OR E/F RELTechnical SpecificationsModel No                    CDG11AF003SACHCDG11APPLICATION               –  E/FBURDEN / D.M.T            –  3VA / 3 SECS.C.T. SECONDARY            –  5 AMP C.T.CASE SIZE                 –  1D V 10TCONTACTS (S/R OR H/R)     –  2 N/O S/RE/F OR U/V SETTING        –  1-4 Amps.FLAG                      –  YESMOUNTING                  –  FLUSHO/C OR O/V SETTING        –  NOT APPLICABLEName Plate                   RFG9126796Outline Diagram              MFJ012Wiring Diagram               MADZ802.63-1

Alstom Over current & Earth fault Protection CDG11AF004SACH
Technical Specification

Type: Electro Mechanical Relay
Protection Type: Over current & Earth fault Protection(IDMT Relay)
GBCDG11AF004SACH
SELF-POWERED INVERSE TIME O/C OR E/F REL

Alstom Auxiliary Relay Agile VAA33ZG8338BCH 110V DC

Request Callback

Get Latest Price

Usage/ApplicationAuxiliary relay
Model Name/NumberVAA33Z
voltage-110 VDC
brandingGE
relay applicationAuxiliary relay
Alstom Auxiliary Relay Agile VAA33ZG8338BCH 110V DCAlstom VAA33ZG8338BCH 110V DC Technical Specification
Type: Electro Mechanical RelayProtection Type: Auxiliary Relay Alstom VAA33ZG8338BCH 110V DC : Type VAA Auxiliary Relays Features
Simple and robust constructionPositive action and high mechanical stabilityHeavy duty contact available, where requiredSlugged relays with delay on operation / reset available in ac/dc version.ApplicationControl, alarm, indication and other auxiliary duties in ac or dc systems.
The type VAA Plug-in-relays is specially designed for industrial control duties requiring respective switching operations. It is capable of providing over
5 million operations without  servicing
and will withstand an operation of up to 600 per hour.
Alstom VAA33ZG8338BCH 110V DC General descriptionVAA relays are voltage operated relays. The relays are attracted armature units of compact design with positive action and a high degree of mechanical stability. The relays can be supplied with self, or hand reset contacts and changeover contacts.
Standard contacts are of silver/copper alloy. They are shaped and positioned to ensure a reliable and low resistance normally open or normally closed contact. Standard VAA 11/21 relays are suitable for ac/dc supply and standard VAA 13/23 relays are suitable for dc supply only.
VAA21/22/23 are double pole versions of VAA 11/12/13 respectively.
VAA 31/33 are Triple pole versions of VAA 11/12/13 respectively.
When it is necessary to break heavy or highly inductive dc loads, heavy duty magnetic blow out type contacts can be provided. These contacts use the magnetic field of a small permanent magnet to force the arc onto the arcing horns away from the contact tips. The breaking capacity of the heavy duty contact is shown by the curves in Figure 1.
Auxiliary relays with delay on pick-up or drop-off can be supplied on specific request. Similarly relays with magnetic blow out contacts can also be supplied on specific request.
The standard VAA relays provide only instantaneous self or hand reset contacts.
To ensure a longer operating life, the tips of the silver contacts have a domed pro- file, the optimum design for the repetitive operation duties of industrial applications.
Although the standard designs are suitable for dc and full-wave rectified ac systems only, alternative versions for ac operation are available.
To explore the comprehensive range of GE/ Alstom Auxiliary, Tripping and lockout relays click here!
Opens in a new window Tweet This Product

Alstom Definite Time Delay Relay VTT11ZG8023LCH, VTT11ZG8024ICH, VTT11ZG8053BCH

Request Callback

Get Latest Price

Model Name/NumberVTT11
voltageDC
BRANDINGGE
USAGETime delay relay
RELAY APPLICATIONTime delay relay
ALSTOM Definite Time Delay Relay VTT11ZG8023LCHALSTOM Definite Time Delay Relay VTT11ZG8023LCH• Type: Electro Mechanical Relay• Protection Type: Definite Time Delay RelayVTT11ZG8023LCHSTATIC DEF TIME DELAY RELAY WITH DELAY OTechnical SpecificationsModel No : VTT11ZG8023LCHVTT11APPLICATION – PICK UPAUX. CURRENT OR VOLTAGE – 220 – 250V ACCASE SIZE – 1/2N H 12TCONTACTS (S/R OR H/R) – 2 N/O 2 N/C S/RFLAG – YESMOUNTING – FLUSHTIME DELAY P/U OR D/O – 0.5 – 5 SECS.External ResistorName Plate RZF9066-601Outline Diagram MFM017Wiring Diagram MZDZ601.02-2
Pioneering key principle advancements over the last 100 years, GE continues to lead the way making new protection, control and automation applications possible. Our solutions continue GE’s century long tradition of power system innovation. From generators to transmission lines, to motors and beyond, we ensure dependable, safe power worldwide. GE offers a wide range of single function and auxiliary relays, along with a portfolio of accessories, to support high performing and reliable protection and control systems.GE offers a wide range of single function and auxiliary relays, along with a portfolio of accessories, to support high performing and reliable protection and control systems.Single Function:Single function protection for applications including overcurrent, voltage and frequency, differential , directional, timing and distance.Auxiliary relays:A variety of auxiliary relays including multicontact, trip and lockout, annunciator and hinged armature relays.

Alstom Definite Time Delay Relay Vtt11zg8024lch

Request Callback

Get Latest Price

Model Name/NumberVTT11
VOLTAGEDC
BRANDINGGE
USAGETime delay relay
RELAY APPLICATIONTime delay relay

ALSTOM Definite Time Delay Relay VTT11ZG8024LCHALSTOM Definite Time Delay Relay VTT11ZG8024LCH• Type: Electro Mechanical Relay• Protection Type: Definite Time Delay Relay• VTT11ZG8024LCHSTATIC DEF TIME DELAY RELAY WITH DELAY OTechnical SpecificationsRELAY MODEL NO – VTT11ZG8024LCHVTT11APPLICATION – PICK UPAUX. CURRENT OR VOLTAGE – 220 – 250V ACCASE SIZE – 1/2N H 12TCONTACTS (S/R OR H/R) – 2 N/O 2 N/C S/RFLAG – YESMOUNTING – FLUSHTIME DELAY P/U OR D/O – 1 – 10 SECS.External ResistorNAME PLATE – RZF9066-601Outline Diagram MFM017Wiring Diagram MZDZ601.02-2
Pioneering key principle advancements over the last 100 years, GE continues to lead the way making new protection, control and automation applications possible. Our solutions continue GE’s century long tradition of power system innovation. From generators to transmission lines, to motors and beyond, we ensure dependable, safe power worldwide. GE offers a wide range of single function and auxiliary relays, along with a portfolio of accessories, to support high performing and reliable protection and control systems.GE offers a wide range of single function and auxiliary relays, along with a portfolio of accessories, to support high performing and reliable protection and control systems.Single Function:Single function protection for applications including overcurrent, voltage and frequency, differential , directional, timing and distance.Auxiliary relays:A variety of auxiliary relays including multicontact, trip and lockout, annunciator and hinged armature relays.

Alstom Definite Time Delay Relay Vtt11zg8053bch

Request Callback

Get Latest Price

Model Name/NumberVTT11
BRANDINGGE / Alstom
VOLTAGEdc
USAGETime delay relay
relay applicationTime delay relay
ALSTOM Definite Time Delay Relay VTT11ZG8053BCHALSTOM Definite Time Delay Relay VTT11ZG8053BCH• Type: Electro Mechanical Relay• Protection Type: Definite Time Delay RelayVTT11ZG8053BCHSTATIC DEF TIME DELAY RELAY WITH DELAY O
Technical SpecificationsModel No : VTT11ZG8053BCHVTT11Application – Pick UpAux. Voltage – 220 – 230 V dcCase Size – 1/2N H 12TContacts – 2 N/O 2 N/C S/RFlag – YesMounting – FlushTiming Range – 0.5 – 5 Secs.External Resistor 3.3 K.OHMS 35 WattsName Plate RZF9066-601Outline Diagram MFM017 & FJ0349Wiring Diagram MZDZ601.01-2
Pioneering key principle advancements over the last 100 years, GE continues to lead the way making new protection, control and automation applications possible. Our solutions continue GE’s century long tradition of power system innovation. From generators to transmission lines, to motors and beyond, we ensure dependable, safe power worldwide. GE offers a wide range of single function and auxiliary relays, along with a portfolio of accessories, to support high performing and reliable protection and control systems.GE offers a wide range of single function and auxiliary relays, along with a portfolio of accessories, to support high performing and reliable protection and control systems.Single Function:Single function protection for applications including overcurrent, voltage and frequency, differential , directional, timing and distance.Auxiliary relays:A variety of auxiliary relays including multicontact, trip and lockout, annunciator and hinged armature relays.

Alstom Definite Time Delay Relay Vtt11zg8054bch

Request Callback

Get Latest Price

Model Name/NumberVTT11
voltageDC
brandingGE / Alstom
applicationTime delay relay
relay applicationTime delay relay
ALSTOM Definite Time Delay Relay VTT11ZG8054BCHALSTOM Definite Time Delay Relay VTT11ZG8054BCH• Type: Electro Mechanical Relay• Protection Type: Definite Time Delay RelayVTT11ZG8054BCHSTATIC DEF TIME DELAY RELAY WITH DELAY O
Technical SpecificationsModel No : – VTT11ZG8054BCHVTT 11APPLICATION – PICK UPAUX.VOLTAGE – 220 – 230 V DCCASE SIZE – 1/2N H 12 TERCONTACTS – 2 N/O 2 N/C S/RFLAG – YESMOUNTING – FLUSHTIME DELAY P/U – 1 – 10 SECS.External Resistor – 3.3 K.OHMSName Plate – RZF9066-601Outline Diagram – MFM017 <(>&<)> FJ0349Wiring Diagram – MZDZ601.01-2
Pioneering key principle advancements over the last 100 years, GE continues to lead the way making new protection, control and automation applications possible. Our solutions continue GE’s century long tradition of power system innovation. From generators to transmission lines, to motors and beyond, we ensure dependable, safe power worldwide. GE offers a wide range of single function and auxiliary relays, along with a portfolio of accessories, to support high performing and reliable protection and control systems.GE offers a wide range of single function and auxiliary relays, along with a portfolio of accessories, to support high performing and reliable protection and control systems.Single Function:Single function protection for applications including overcurrent, voltage and frequency, differential , directional, timing and distance.
Auxiliary relays:A variety of auxiliary relays including multicontact, trip and lockout, annunciator and hinged armature relays.
Opens in a new window

Alstom Definite Time Delay Relay Vtt11zg8142bch

Request Callback

Get Latest Price

Model Name/NumberVTT11
brandingGE / Alstom
voltagedc
applicationTime delay relay
relay applicationTime delay relay
ALSTOM Definite Time Delay Relay VTT11ZG8142BCHALSTOM Definite Time Delay Relay VTT11ZG8142BCH• Type Electro Mechanical Relay• Protection Type Definite Time Delay RelayVTT11ZG8142BCHSTATIC DEF TIME DELAY RELAY WITH DELAY OTechnical SpecificationsModel No : VTT11ZG8142BCHVTT11Application – Pick UPAux. Voltage – 110 – 125 V dcCase Size – 1/2N H 12TContacts Output – 2 N/O 2 N/C S/RFlag – YesMounting – FlushTiming Range – 0.1 – 1 SecsExternal Resistor 1.3 K OhmsName Plate RZF9066-601Outline Diagram MFM017 & FJ0349
Pioneering key principle advancements over the last 100 years, GE continues to lead the way making new protection, control and automation applications possible. Our solutions continue GE’s century long tradition of power system innovation. From generators to transmission lines, to motors and beyond, we ensure dependable, safe power worldwide. GE offers a wide range of single function and auxiliary relays, along with a portfolio of accessories, to support high performing and reliable protection and control systems.GE offers a wide range of single function and auxiliary relays, along with a portfolio of accessories, to support high performing and reliable protection and control systems.Single Function:Single function protection for applications including overcurrent, voltage and frequency, differential , directional, timing and distance.Auxiliary relays:A variety of auxiliary relays including multicontact, trip and lockout, annunciator and hinged armature relays. Pioneering key principle advancements over the last 100 years, GE continues to lead the way making new protection, control and automation applications possible. Our solutions continue GE’s century long tradition of power system innovation. From generators to transmission lines, to motors and beyond, we ensure dependable, safe power worldwide. GE offers a wide range of single function and auxiliary relays, along with a portfolio of accessories, to support high performing and reliable protection and control systems.GE offers a wide range of single function and auxiliary relays, along with a portfolio of accessories, to support high performing and reliable protection and control systems.Single Function:Single function protection for applications including overcurrent, voltage and frequency, differential , directional, timing and distance.Auxiliary relays:A variety of auxiliary relays including multicontact, trip and lockout, annunciator and hinged armature relays.

Alstom Definite Time Delay Relay Vtt11zg8143bch

Request Callback

Get Latest Price

Model Name/NumberVTT11
voltageDC
brandingGE / Alstom
usageTime delay relay
relay applicationTime delay relay
ALSTOM Definite Time Delay Relay VTT11ZG8143BCHDefinite Time Delay Relay VTT11ZG8143BCH Technical Specification• Type: Electro Mechanical Relay• Protection Type: Definite Time Delay Relay

VTT11ZG8143BCHSTATIC DEF TIME DELAY RELAY WITH DELAY O

Technical SpecificationsModel No : VTT11ZG8143B(M)VTT11

APPLICATION – PICK UPAUX. CURRENT OR VOLTAGE – 110V DCCASE SIZE – 1/2N H 12TCONTACTS (S/R OR H/R) – 2 N/O 2 N/C S/RFLAG – YESMOUNTING – FLUSHTIME DELAY P/U OR D/O – 0.5 – 5 SECS.External Resistor 1.3 K.OHMSName Plate RZF9066-601Outline Diagram MFM017 & FJ0349Wiring Diagram MZDZ601.01-2
Check synchronising relays are used to prevent interconnection of badly synchronised supplies. Type SKD relays are generally used in auto reclosing sequence of interconnectors along with the auto reclosing relay. Type SKE relays are used to safeguard manual synchronising of generators. The check synchronising relay contacts are normally connected in series with the circuit breaker closing circuit and ensures that the differences in phase, voltage and frequency are within pre-selected limits before switching in an incoming alternator or interconnecting two sections of a power system.
Features Low burden, static
Accurate andImmune to transient and surges; withstands 5 kV impulse voltageTime Delay Relay VTT11ZG8143BCH General DescriptionPhase difference measurement Phase measurement is achieved by algebraically subtracting the two supply voltage waveforms and comparing the resultant modulated beat waveform envelope with a dc reference voltage (See Figure 1).
The dc reference is proportioned to the sum of the peaks of the two supply voltages to provide phase measurement independent of supply voltage variation. Referring to Figure 2, the resulting voltage produced after subtraction is passed via the gate (which is opened when the VTI supply is present) to the phase angle comparator and integrating amplifier.
The signal is compared with the dc reference and produces a smoothed output to the relay drive unit if the signal is less than dc reference. The relay drive circuit prevents chatter of the relay at the just-operate condition.
Frequency difference measurement Frequency difference measurement is achieved by checking that the phase angle traversed in a defined period is less than
a pre-determined value. Referring to the block diagram the output from the phase measurement circuit drives an accurately calibrated timer. The timer operates the relay on completion of its timing cycle, if the output from the phase measurement circuit persists.
The relationship between timer setting and frequency difference is given in Table 1.
Voltage difference measurement Two types of voltage lockout are available. Type SKD compares the amplitude of the two supply voltages, with a stabilized dc reference which is proportioned to the nominal supply voltage. The Voltage lockout circuit inhibits the gate if either voltage is below the preset limit. Type SKE compares the two supply voltages and inhibits the gate if the difference between the supply voltages exceeds the preset limit.

Alstom Definite Time Delay Relay Vtt11zg8178bch

Request Callback

Get Latest Price

Model Name/NumberVTT11
voltageDC
brandingGE / Alstom
relay applicationTime delay relay
usageTime delay relay
GE / ALSTOM DEFINITE TIME DELAY RELAY VTT11ZG8178BCHAlstom Definite Time Delay Relay VTT11ZG8178BCH
• Type: Electro Mechanical Relay• Protection Type: Definite Time Delay Relay
GBVTT11ZG8178BCHSTATIC DEF TIME DELAY RELAY WITH DELAY O
Technical SpecificationsModel No : – VTT11ZG8178B(M) – VTT11APPLICATION – PICK UPAUX. CURRENT OR VOLTAGE – 24 – 30V DCCASE SIZE – 1/2N H 12TCONTACTS (S/R OR H/R) – 2 N/O 2 N/C S/RFLAG – YESMOUNTING – FLUSHTIME DELAY P/U OR D/O – 0.1 – 1 SEC.Name Plate – RZF9066-601Outline Diagram – MFM017Wiring Diagram – MZDZ601.01-2
Time Delay Relay VTT11ZG8178BCH Features Low burden, static
Accurate andImmune to transient and surges; withstands 5 kV impulse voltageGeneral DescriptionPhase difference measurement Phase measurement is achieved by algebraically subtracting the two supply voltage waveforms and comparing the resultant modulated beat waveform envelope with a dc reference voltage (See Figure 1).
The dc reference is proportioned to the sum of the peaks of the two supply voltages to provide phase measurement independent of supply voltage variation. Referring to Figure 2, the resulting voltage produced after subtraction is passed via the gate (which is opened when the VTI supply is present) to the phase angle comparator and integrating amplifier.
The signal is compared with the dc reference and produces a smoothed output to the relay drive unit if the signal is less than dc reference. The relay drive circuit prevents chatter of the relay at the just-operate condition.
Frequency difference measurement Frequency difference measurement is achieved by checking that the phase angle traversed in a defined period is less than
a pre-determined value. Referring to the block diagram the output from the phase measurement circuit drives an accurately calibrated timer. The timer operates the relay on completion of its timing cycle, if the output from the phase measurement circuit persists.
The relationship between timer setting and frequency difference is given in Table 1.
Voltage difference measurement Two types of voltage lockout are available. Type SKD compares the amplitude of the two supply voltages, with a stabilized dc reference which is proportioned to the nominal supply voltage. The Voltage lockout circuit inhibits the gate if either voltage is below the preset limit. Type SKE compares the two supply voltages and inhibits the gate if the difference between the supply voltages exceeds the preset limit.

Alstom Definite Time Delay Relay Vtt11zg8179bch

Request Callback

Get Latest Price

Model Name/NumberVTT11
voltageDC
brandingGE / Alstom
usageTime delay relay
relay applicationTime delay relay
ALSTOM DEFINITE TIME DELAY RELAY VTT11ZG8179BCHTime Delay Relay VTT11ZG8179BCH specifications:
• Type: Electro Mechanical Relay• Protection Type: Definite Time Delay Relay• GBVTT11ZG8179BCH

STATIC DEF TIME DELAY RELAY WITH DELAY O
Technical SpecificationsModel No : VTT11ZG8179BCHVTT11APPLICATION – PICK UPAUX. CURRENT OR VOLTAGE – 24 – 30V DCCASE SIZE – 1/2N H 12TCONTACTS (S/R OR H/R) – 2 N/O 2 N/C S/RFLAG – YESMOUNTING – FLUSHTIME DELAY P/U OR D/O – 0.5 – 5 SECS.External ResistorName Plate RZF9066-601Outline Diagram MFM017Wiring Diagram MZDZ601-01-2
VTT11ZG8180BCH Definite Time Delay Features Low burden, static
Accurate andImmune to transient and surges; withstands 5 kV impulse voltageGeneral DescriptionPhase difference measurement Phase measurement is achieved by algebraically subtracting the two supply voltage waveforms and comparing the resultant modulated beat waveform envelope with a dc reference voltage (See Figure 1).
The dc reference is proportioned to the sum of the peaks of the two supply voltages to provide phase measurement independent of supply voltage variation. Referring to Figure 2, the resulting voltage produced after subtraction is passed via the gate (which is opened when the VTI supply is present) to the phase angle comparator and integrating amplifier.
The signal is compared with the dc reference and produces a smoothed output to the relay drive unit if the signal is less than dc reference. The relay drive circuit prevents chatter of the relay at the just-operate condition.
Frequency difference measurement Frequency difference measurement is achieved by checking that the phase angle traversed in a defined period is less than
a pre-determined value. Referring to the block diagram the output from the phase measurement circuit drives an accurately calibrated timer. The timer operates the relay on completion of its timing cycle, if the output from the phase measurement circuit persists.
The relationship between timer setting and frequency difference is given in Table 1.
Voltage difference measurement Two types of voltage lockout are available. Type SKD compares the amplitude of the two supply voltages, with a stabilized dc reference which is proportioned to the nominal supply voltage. The Voltage lockout circuit inhibits the gate if either voltage is below the preset limit. Type SKE compares the two supply voltages and inhibits the gate if the difference between the supply voltages exceeds the preset limit.

Alstom Definite Time Delay Relay VTT11ZG8180BCH

Request Callback

Get Latest Price

Model Name/NumberVTT11
voltageDC
brandingGE / Alstom
relay applicationTime delay relay
usageTime delay relay
ALSTOM DEFINITE TIME DELAY RELAY VTT11ZG8180BCHVTT11ZG8180BCH Definite Time Delay Technical Specifications
Type: Electro Mechanical RelayProtection Type: Definite Time Delay RelayGBVTT11ZG8180BCHSTATIC DEF TIME DELAY RELAY WITH DELAY O
Technical SpecificationsModel No – VTT11ZG8180BCHVTT11APPLICATION – PICK UPAUX. CURRENT OR VOLTAGE – 24 – 30V DCCASE SIZE – 1/2N H 12TCONTACTS (S/R OR H/R) – 2 N/O 2 N/C S/RFLAG – YESMOUNTING – FLUSHTIME DELAY P/U OR D/O – 1 – 10 SECS.External ResistorName Plate RZF9066-601Outline Diagram MFM017Wiring Diagram MZDZ601-01-2
Check synchronising relays are used to prevent interconnection of badly synchronised supplies. Type SKD relays are generally used in auto reclosing sequence of interconnectors along with the auto reclosing relay. Type SKE relays are used to safeguard manual synchronising of generators. The check synchronising relay contacts are normally connected in series with the circuit breaker closing circuit and ensures that the differences in phase, voltage and frequency are within pre-selected limits before switching in an incoming alternator or interconnecting two sections of a power system.
VTT11ZG8180BCH Definite Time Delay Features Low burden, static
Accurate andImmune to transient and surges; withstands 5 kV impulse voltageGeneral DescriptionPhase difference measurement Phase measurement is achieved by algebraically subtracting the two supply voltage waveforms and comparing the resultant modulated beat waveform envelope with a dc reference voltage (See Figure 1).
The dc reference is proportioned to the sum of the peaks of the two supply voltages to provide phase measurement independent of supply voltage variation. Referring to Figure 2, the resulting voltage produced after subtraction is passed via the gate (which is opened when the VTI supply is present) to the phase angle comparator and integrating amplifier.
The signal is compared with the dc reference and produces a smoothed output to the relay drive unit if the signal is less than dc reference. The relay drive circuit prevents chatter of the relay at the just-operate condition.
Frequency difference measurement Frequency difference measurement is achieved by checking that the phase angle traversed in a defined period is less than
a pre-determined value. Referring to the block diagram the output from the phase measurement circuit drives an accurately calibrated timer. The timer operates the relay on completion of its timing cycle, if the output from the phase measurement circuit persists.
The relationship between timer setting and frequency difference is given in Table 1.
Voltage difference measurement Two types of voltage lockout are available. Type SKD compares the amplitude of the two supply voltages, with a stabilized dc reference which is proportioned to the nominal supply voltage. The Voltage lockout circuit inhibits the gate if either voltage is below the preset limit. Type SKE compares the two supply voltages and inhibits the gate if the difference between the supply voltages exceeds the preset limit.

Alstom Numerical Feeder Protection Relay Agile P14db

Request Callback

Get Latest Price

voltage220-240V
brandGE
usagefeeder protection
model noP14DB
relay applicationfeeder protection
ALSTOM NUMERICAL FEEDER PROTECTION RELAY AGILE P14DBTechnical Specification
• Type: Numerical Relay
• Protection Type: Feeder
• Protocol: Modbus / IEC103 / 61850
• Voltage: 24V-240V
P40 Agile Feeder Management
The P14N non-directional feeder, P14D directional feeder and P94V voltage and frequency IEDs bring the design rigor and technology of transmission applications to the entire utility and industrial market. The footprints of both the device physical size and the lifecycle environmental impact have been minimized using state-of-the-art design, component, and process selection. Agile solutions from GE are ideal for new-build and retrofit alike.
Agility and Versatility
MiCOM P40 Agile IEDs provide an integrated solution for the complete protection, control and monitoring of electrical power systems. Application for overhead lines, underground cables, busbars, breakers, transformers, reactors and distributed generation is supported, right from distribution (as primary protection) to transmission voltage levels (as back-up). The IEDs are suitable for a wide variety of applications in solidly-earthed, resistance-earthed and Petersen coil systems.
Key Benefits
Comprehensive current, voltage, power and frequency protectionMulti-stage independent protection elements, customizable curvesUniversal power supply, binary input ratings and 1A/5A CT – avoids order optionsRecords up to 2048 events, graphical logic engine, distance-to-fault locationTwo stage circuit breaker failure and breaker condition monitoringSwitchgear supervision including CT/VT, DC supply, full ‘H7’ trip circuit supervisionSubstation communications including IEC 61850, serial and concurrent protocolsCompact, withdrawable design for reduced space applicationsEcodesigned with Product Environmental Profile (PEP), no resident battery

Alstom Check Synchronising Relay Ske11bf8005bch

Request Callback

Get Latest Price

Voltage30 VDC
Usage/ApplicationCheck synchronizing relay
BrandingGE
model noSke11bf8005bch
relay applicationCheck synchronizing relay
ALSTOM CHECK SYNCHRONISING RELAY SKE11BF8005BCHCheck Synchronising Relay SKE11BF8005BCH Technical Specification
Type: Electro Mechanical RelayProtection Type: Check Synchronising Relay Check synchronising relays are used to prevent interconnection of badly synchronised supplies. Type SKD relays are generally used in auto reclosing sequence of interconnectors along with the auto reclosing relay. Type SKE relays are used to safeguard manual synchronising of generators. The check synchronising relay contacts are normally connected in series with the circuit breaker closing circuit and ensures that the differences in phase, voltage and frequency are within pre-selected limits before switching in an incoming alternator or interconnecting two sections of a power system.
Check Synchronising Relay SKE11BF8002BCH Features Low burden, staticAccurate andImmune to transient and surges; withstands 5 kV impulse voltageGeneral DescriptionPhase difference measurement Phase measurement is achieved by algebraically subtracting the two supply voltage waveforms and comparing the resultant modulated beat waveform envelope with a dc reference voltage (See Figure 1).
The dc reference is proportioned to the sum of the peaks of the two supply voltages to provide phase measurement independent of supply voltage variation. Referring to Figure 2, the resulting voltage produced after subtraction is passed via the gate (which is opened when the VTI supply is present) to the phase angle comparator and integrating amplifier.
The signal is compared with the dc reference and produces a smoothed output to the relay drive unit if the signal is less than dc reference. The relay drive circuit prevents chatter of the relay at the just-operate condition.

Alstom Check Synchronising Relay Ske11bf8042bch

Request Callback

Get Latest Price

Voltage220-240V
Usage/ApplicationCheck synchronizing relay
BrandGE
MODEL NOSke11bf8042bch
RELAY APPLICATIONCheck synchronizing relay
Alstom Check Synchronising Relay SKE11BF8042BCHTechnical Specification
Type: Electro Mechanical RelayProtection Type: Check Synchronising RelayGBSKE11BF8042BCH
CHECK SYN RELAY FOR MANUAL SYN OF GENERA
Technical SpecificationsModel No :         SKE11BF8042B(M)Relay type           SKE11CASE SIZE            1D V 20TAUX. CURRENT OR VOLTAGE      110/125V DCMTA Phase-Char Angle 10 DegreesCONTACTS (S/R OR H/R)               2 N/O S/RSETTING               2 – 10% (ADJ. VOLTS)TIME DELAY P/U OR D/O               0.25 – 1.5 SECS.Frequency          50 HZV.T/P.T SECONDARY       63.5 / 110 V ACFLAG                     NoExternal Resistor              1 K.OHMName Plate        MZF9008-002Outline Diagram               MFJ012 & FJ0349Wiring Diagram                 MBDZ608-1 
Pioneering key principle advancements over the last 100 years, GE continues to lead the way making new protection, control and automation applications possible. Our solutions continue GE’s century long tradition of power system innovation. From generators to transmission lines, to motors and beyond, we ensure dependable, safe power worldwide. GE offers a wide range of single function and auxiliary relays, along with a portfolio of accessories, to support high performing and reliable protection and control systems.GE offers a wide range of single function and auxiliary relays, along with a portfolio of accessories, to support high performing and reliable protection and control systems.Single Function:Single function protection for applications including overcurrent, voltage and frequency, differential , directional, timing and distance.Auxiliary relays:A variety of auxiliary relays including multicontact, trip and lockout, annunciator and hinged armature relays.

Alstom Numerical Feeder Protection Relay Agile P142

Request Callback

Get Latest Price

voltage220-240V
brandGE
usagefeeder protection
model noP142
relay applicationfeeder protection
Alstom Numerical Feeder Protection relay Agile P142MiCOM Agile P142 feeder management relays provide an integrated solution for the complete protection, control and monitoring of overhead lines and underground cables, covering all distribution and transmission voltage levels. Providing all essential information to efficiently maintain complex power systems and their components, the P142 relay family is user-friendly and highly flexible, allowing application on any network.
The MiCOM Agile P142 is an advanced feeder management relay platform with overcurrent and earth fault protection, as well as autoreclose and a full suite of protection, control and monitoring functions. The platform also provides main or back-up protection for MV/HV, solidly earthed, impedance earthed, Petersen coil earthed and isolated neutral systems.
Full feeder management with efficient monitoring, control, recording and digital communicationsSupports all major digital control system protocols, easing integration into DCS, SCADA and engineering workstationsHarsh environment protection extends the life of the productNew advanced opto inputs comply with the harshest norms for surge withstand, plus the ESI 48-4 EB2 standard. Spurious wiring pickup is eliminated without the use of interposing relays, external resistors or time delays. Battery/wiring faults, switching noise, and induction from long parallel circuits are tolerated without misoperation.Opens in a new window

Alstom Numerical Feeder Protection Relay Agile P143

Request Callback

Get Latest Price

voltage220-240V
brandGE
usagefeeder protection
model noP143
relay applicationfeeder protection
Alstom Numerical Feeder Protection relay Agile P143
MiCOM Agile P143 feeder management relays provide an integrated solution for the complete protection, control and monitoring of overhead lines and underground cables, covering all distribution and transmission voltage levels. Providing all essential information to efficiently maintain complex power systems and their components, the P143 relay family is user-friendly and highly flexible, allowing application on any network.

The MiCOM Agile P143 is an advanced feeder management relay platform with overcurrent and earth fault protection, as well as autoreclose and a full suite of protection, control and monitoring functions. The platform also provides main or back-up protection for MV/HV, solidly earthed, impedance earthed, Petersen coil earthed and isolated neutral systems.

Features

Full feeder management with efficient monitoring, control, recording and digital communications
Supports all major digital control system protocols, easing integration into DCS, SCADA and engineering workstations
Harsh environment protection extends the life of the product
New advanced opto inputs comply with the harshest norms for surge withstand, plus the ESI 48-4 EB2 standard. Spurious wiring pickup is eliminated without the use of interposing relays, external resistors or time delays. Battery/wiring faults, switching noise, and induction from long parallel circuits are tolerated without misoperation.

GE/ Alstom P50 Agile P154 Feeder Protection

Request Callback

Get Latest Price

VOLTAGE220-240V
BRANDGE
usagefeeder protection
model noP154
relay applicationfeeder protection
GE/ ALSTOM P50 AGILE P154 FEEDER PROTECTION
The Agile P154 relay provides non directional overcurrent and earth fault for MV/LV and HV backup feeder protection. The relay features a wide range of measurement, protection and monitoring functions and is easily customizable using programmable BI/BO/LEDs/AND logic. The P154 is economical, designed for deployment in volume in lower voltage systems, as a backup relay in HV systems, or as direct refurbishment of non-communicating overcurrent relays.

The principal protection functions are timed and instantaneous phase and earth fault protection, with up to 3 independent stages available. Additional versatility is provided through negative sequence overcurrent, thermal overload, cold load pickup, inrush blocking, broken conductor, breaker fail, restricted earth fault, undercurrent/loss of load, and trip circuit supervision functions. The hardware capability is broadened by a sensitive earth fault CT option, and a universal auxiliary power supply range to permit standardization in procurement and inventories.

Key Benefits:

Optimized protection for feeder applications
Cost effective
Measurement, protection and monitoring in one box
Front USB port for local communication
Flexible SCADA communication options
Diagnostics/maintenance facilities
Universal, wide-range auxiliary supply
Password protection for security
Extensive self-supervision and internal diagnostics

Alstom Numerical Feeder Protection Relay Agile P14DA, P14DB, P14NB

Request Callback

Get Latest Price

VOLTAGE220-240V
BRANDGE
USAGEfeeder protection
MODEL NOP14DA
RELAY APPLICATIONfeeder protection
ALSTOM NUMERICAL FEEDER PROTECTION RELAY AGILE P14DA
Technical Specification

• Type Numerical Relay

• Protection Type Feeder

• ProtocolModbus / IEC103

• Voltage24V-240V

• ACDC OperatedAuxillary supply AC/DC

P40 Agile Feeder Management

The P14N non-directional feeder, P14D directional feeder and P94V voltage and frequency IEDs bring the design rigor and technology of transmission applications to the entire utility and industrial market. The footprints of both the device physical size and the lifecycle environmental impact have been minimized using state-of-the-art design, component, and process selection. Agile solutions from GE are ideal for new-build and retrofit alike.

Agility and Versatility

MiCOM P40 Agile IEDs provide an integrated solution for the complete protection, control and monitoring of electrical power systems. Application for overhead lines, underground cables, busbars, breakers, transformers, reactors and distributed generation is supported, right from distribution (as primary protection) to transmission voltage levels (as back-up). The IEDs are suitable for a wide variety of applications in solidly-earthed, resistance-earthed and Petersen coil systems.

Key Benefits

Comprehensive current, voltage, power and frequency protection
Multi-stage independent protection elements, customizable curves
Universal power supply, binary input ratings and 1A/5A CT – avoids order options
Records up to 2048 events, graphical logic engine, distance-to-fault location
Two stage circuit breaker failure and breaker condition monitoring
Switchgear supervision including CT/VT, DC supply, full ‘H7’ trip circuit supervision
Substation communications including IEC 61850, serial and concurrent protocols
Compact, withdrawable design for reduced space applications
Ecodesigned with Product Environmental Profile (PEP), no resident battery

Alstom Numerical Feeder Protection Relay Agile P14da

Request Callback

Get Latest Price

TypeIndustrial Relay
Frequency50/60Hz
BRANDGE
VOLTAGE220-240V
USAGE / APPLICATIONfeeder protection
ALSTOM NUMERICAL FEEDER PROTECTION RELAY AGILE P14DATechnical Specification
• Type Numerical Relay
• Protection Type Feeder
• ProtocolModbus / IEC103
• Voltage24V-240V
• ACDC OperatedAuxillary supply AC/DC
P40 Agile Feeder Management
The P14N non-directional feeder, P14D directional feeder and P94V voltage and frequency IEDs bring the design rigor and technology of transmission applications to the entire utility and industrial market. The footprints of both the device physical size and the lifecycle environmental impact have been minimized using state-of-the-art design, component, and process selection. Agile solutions from GE are ideal for new-build and retrofit alike.
Agility and Versatility
MiCOM P40 Agile IEDs provide an integrated solution for the complete protection, control and monitoring of electrical power systems. Application for overhead lines, underground cables, busbars, breakers, transformers, reactors and distributed generation is supported, right from distribution (as primary protection) to transmission voltage levels (as back-up). The IEDs are suitable for a wide variety of applications in solidly-earthed, resistance-earthed and Petersen coil systems.
Key Benefits
Comprehensive current, voltage, power and frequency protectionMulti-stage independent protection elements, customizable curvesUniversal power supply, binary input ratings and 1A/5A CT – avoids order optionsRecords up to 2048 events, graphical logic engine, distance-to-fault locationTwo stage circuit breaker failure and breaker condition monitoringSwitchgear supervision including CT/VT, DC supply, full ‘H7’ trip circuit supervisionSubstation communications including IEC 61850, serial and concurrent protocolsCompact, withdrawable design for reduced space applicationsEcodesigned with Product Environmental Profile (PEP), no resident battery
X

Contact Us

Karan Agarawal (Director)
Maxxcom System Private Limited
Shop No A-6, Ratna Business Hub, Near Petrol Pump, Navapura
Ahmedabad - 382210, Gujarat, India

Get Directions
Send Email
Share: